Know More UTS-280 Digital Ultrasonic Flaw Detector Overview UTS-280 is a portable industrial non-destructive flaw detector, which can rapidly, easily and accurately inspect, locate, evaluate and diagnose various defects (crack, inclusion and pinhole, etc.) in a workpiece without destruction. It can be used both in a lab and field. The instrument can be widely used in any fields that need defect inspection and quality controlling e.g. manufacturing industry, iron & steel metallurgical industry, metalworking, chemical industry, etc., also be broadly used in the active safety inspection and service-life evaluation in such fields as aerospace, railway transportation and boiler pressure vessels, etc. It is an essential instrument for non-destructive inspection industry. When the ultrasonic wave propagates in a job, one can detect the defect in it by the influence on the propagation of ultrasonic wave based on the acoustic characteristic demonstrated by the defect in the material. Based on this principle, by using ultrasonic wave one can measure such defects as crack, pinhole and inclusion in such media as metal, non metal and composite, etc. Basic working principle for ultrasonic detection Advantages: ★ Automated calibration (IIW, two hole), Automated gain ★ DAC, AVG, TCG, B scan, AWS, No Limited Video record, ★ High-speed capture and very low noise ★ high contrast viewing of the waveform from bright ★ Powerful pc software and reports can be export to excel ★ Spheroidization Rate Measurement ★ 28 DGS Curves Performance Features 1. Automated calibration of transducer Zero Offset and/or Velocity 2. Automated gain, Peak Hold and Peak Memory 3. Automated display precise flaw location(Depth d, level p, distance s, amplitude, sz dB, ф) 4. Automated switch three staff gauge ((Depth d, level p, distance s) 5. 500 independence setup, any criterion can be input freely, we can work in the scene without test block 6. Big memory of 1000 A graph 7. Gate and DAC alarm, Acoustic-Optical alarm 8. USB port, communication with pc is easy 9. The embed software can be online updated 10. Li battery, continue working time up to 12 hours 11. Display freeze 12. Automated echo degree 13. Angles and K-value 14. Lock and unlock function of system parameters 15. AWS D1.1 16. Dormancy and screen savers 17. Electronic clock calendar 18. There are 14 standards of DAC in UTS-280. 19. Automated make video of test process and play Connect the USB Disk, the length of video is unlimited 20. Two gates setting and alarm indication 21. High-speed capture and very low noise 22. DAC, AVG, TCG, B Scan, Solid plastic housing (IP65) 23. Automated calculate the size of the flaw with w ide bottom type in AVG function 24. 6dB DAC functions 25. Provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness and easy to read from all angles 26. Powerful pc software and reports can be export to excel 2.6 Technical Parameters Designation Technical Data Range of scanning (mm) Range of scanning (mm): 0-10000 Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300,350,400,450,500,600,700,800,900,1000,2000,3000,4000,5000,6000,7000,8000,9000,10000 Adjusting step: 0.1mm(2.5 mm-99.9mm), 1mm(100mm-10000mm) D-delay (ms) D-delay (ms): -20-+3400 Steps:-20,-10,0.0,10,20,50,100,150,200,250,300,350,400,450,500, 600,700,800,900,1000,1500,2000,2500,3000,3400. Adjusting steps: 0.1(-20ms-999.9ms), 1(1000ms-3400ms) P-delay (ms) P-delay: 0.0-99.99 Adjusting steps: 0.01 MTLVEL(m/s) MTLVEL:1000-15000 10 fixed levels: 2260,2730,3080,3230,4700,5920,630012000,13000,14000,15000 Adjusting steps: 1 Working mode Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe) Frequency Range (MHz) 0.2-20 Gain adjustment (dB) 0-130 Adjusting step: 0.0, 0.1, 0.5, 1, 2, 6, 12 Reject 0%-80% of screen height, step: 1% Vertical linear error Vertical linear error is not more than 3% Horizontal linear error Not more than 0.2% in the scanning range Sensitivity Leavings ≥62 dB Dynamic range ≥34dB Alarm Three modes, i.e. forbidden wave, loss wave and auto A-Scan display area Full screen or local A-Scan display freezing and de-freezing A-Scan filling Data save 1000 A-Scan images (including setting of instrument) Standard communication interface with PC USB Measuring unit Mm / inch Battery Li battery 7.4V 4800mAh Power adaptor Input 100V-240V / 50Hz-60Hz Output 9VDC / 1.5A Working temperature -20℃-50℃ Working humidity 20%-90% Port type BNC / LEMO Overall dimension (mm) 50x160x238 Weight (kg) 1.0 Standard Configuration No. Item Quantity 1 Main Body 1 2 Straight Beam Probe 2.5MHz, 20mm 1 3 Angle Probe 4MHz, 8*9, 60 degree 1 4 Machine-probe Cable 2 5 Battery Module 1 6 1.5A/9V Power Adapter (Charger) 1 7 Instruction Manual in English 1 8 Instrument Carrying case 1 9 USB cable 1 10 Communication software for PC 1 |
Automotive Type | |
Type | : Automatic |
More Details |
|
Maximum Retail Price (inclusive of all taxes) | : Rs.0 |
Common or Generic Name | : - |
Net Contents / Net Quantity | : - |
Manufacturer's Name and Address | : - |
Packer's Name and Address | : - |
Marketer's name and Address | : - |
Importer's Name and Address | : - |
Country of Origin / Manufacture / Assembly | : India |